Environment & Power Systems International
USA
(763) 222-9532
The ASETM8 industrial gas turbine volatile organic compound (VOC) oxidizer (GTO) is designed to replace conventional VOC air pollution control devices including the regenerative thermal oxidizer (RTO).
Gas Turbine Oxidizer (GTO)
Performance and Operability
Fast start
Fuel flexible
Annual oil change
Heavy duty construction
Continuous or intermittent duty
Air cooled gas turbine and genset
Operates in harsh environments
Lower maint. costs/schedules vs. RTO
VOC destruction 97-99.99%
VOCs displace pilot fuel requirements
adsorbing variable VOC loading rates
Instant adjustment to high VOC loads
High VOC loading rates
VOC laden air <180,000CFM with VOC concentrator
Summary of Specifications
VOC combustion air volume:
6,200 scfm (166nm3/min
Power Generated 525kW @ ISO
Heat rate 15,448 BTU/ kWh
Heat recovery 4,500 lbs./hr stream
90,000lbs./hr hot water
Exhaust gas temperature 925°F (496°C)
Exhaust gas flow 7.9lb/sec (3.6kg/sec)
Fuel: NG / diesel / Jet-A / biofuel
Fuel Flow <4,12lb/hr (187 kg/hr) (7.9MMBtu/hr)
Engine Pressure Ratio 10.6
Generator Set Enclosure
Sound attenuated and environmentally protected for outdoor-rated use in standard or ISO Container designs.